The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Wa state irc roof vent.
As an example of what you can find in chapter 8 of the 2018 irc see.
Roof sheathing shall be structural wood panels plywood osb with a minimum five eighths inch thickness grade stamped for use and span.
Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof framing members shall have cross ventilation for each separate space by ventilation openings protected against the entrance of rain and snow.
2006 washington state ventilation indoor air quality code effective july 1 2007 note.
The state building council is a state agency created by the legislature to provide independent analysis and objective advice to the legislature and the governor s office on state building code issues.
Chapter 8 roof ceiling construction.
Provided that chapters 11 and 25 through 43 of this code are not adopted.
This code will be repealed as of july 1 2010.
On the upcodes website.
Plumbing code is regulated by chapter 51 56 wac.
Secure roof sheathing panels to the roof framing with 8d common nails spaced six inches on center at the edges and twelve inches on center at intermediate supports.
Contains sections covering roof framing roof sheathing and roof ventilation.
The requirements formerly found in this wac are now incorporated into the imc and irc.
The council establishes the minimum building mechanical fire plumbing and energy code requirements necessary to promote the health safety and.
The 2018 washington state building code will be effective february 1 2021 and comprised of the following codes.
2018 international residential code.
2003 washington state ventilation indoor air quality code effective july 1 2004.
2018 international building code includes adoption of and amendments to the 2018 international existing building code and icc ansi a117 1 2009 and the international swimming pool and spa code.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Roof coverings such as shingle tiles rubber plastic or metal must be rated as a class a fire retardant material.
This is a requirement for homeowners insurance in washington state and has been built into the local building codes to prevent the use of inferior roof covering products and to help facilitate updating homes from the old roofing products to the new roofing products.
Blocking and bridging shall be arranged so as not to interfere with the movement of air.
Overflow drains having the same size as the roof drains shall be installed with the inlet flow line located 2 inches 51 mm above the low point of the roof or overflow scuppers having three times the size of the roof drains and having a minimum opening height of 4 inches 102 mm shall be installed in the adjacent parapet walls with the inlet flow located 2 inches 51 mm above the low point of the roof served.
The 2018 edition of the international residential code as published by the international code council is hereby adopted by reference with the following additions deletions and exceptions.