The installation is roughly in keeping with the standard practice of using housewrap on exterior surfaces.
Wind washing attic 1 2 story.
Investigating solutions to wind washing issues in two story florida homes phase 2.
It s a 1 1 2 story home built in 1949.
Testing was designed to identify wind washing potential overall house tightness duct leakage to outdoors and air pressure boundaries.
Characterize wind washing failures of the house air and thermal boundary.
Allows your attic insulation to function at optimal levels by eliminating wind washing which is when the fresh air from the soffits travels through your attic insulation and degrades its performance.
Install baffles at each rafter bay with a soffit vent to direct air flow and wind above rather than through attic insulation.
Identify areas of the home likely to be affected by wind washing e g attic soffit vents cantilevered floors open porch ceilings adjacent to second story floor cavities.
This would reduce wind washing of the insulation.
The space between the ceiling beams of the top story and the roof rafters.
The national renewable energy laboratory.
Factor is equivalent to the earlier use of a 1 3 wind load factor in that the newer wind load provisions of asce 7 98 include separate consideration of wind directionality by adjusting wind loads by an explicit wind directionality factor kd of 0 85.
On behalf of the u s.
15013 denver west parkway.
A half story is that portion of a building under the roof the wall plates of which on at least two opposite exterior walls are not more than four and one half feet above the finished floor of such story.
Your attic must be insulated very well because it will include appliances that need to be kept away from moisture or excessive heat.
Department of energy s building america program.
Provides maximum insulation more than double that of fiberglass or cellulose in the very tight but critical area of your exterior wall top.
The roof is newer and insulating the exterior of the roof is not an.
Golden co 80401.
The kneewalls have exposed fiberglass batts.
Office of energy efficiency and renewable energy.
I don t know about the floor yet.
Attic or storyfrom the 2006 ibc commentaryattic.
What could you be done that is worthwhile for the second floor.
You will want to feel comfortable while washing or ironing the clothes and for this you will have to insulate the attic so it will not lose heat or cool air and it will not have humidity issues.
There is a limited budget to do upgrades.
In my opinion you could put housewrap on the back side of the second floor kneewalls in a well ventilated attic.
The rafters are 2 x4s with fiberglass batts between the ceiling and the roof.
Since the wind load factor of 1 3 included this effect it must be.
The definition of attic identifies the specific portion of a building or structure for the purposes of determining the applicability of requirements that are specific to at tics such as ventilation see section 1202 and draftstopping see section 716.
As for the attic floor i would not put a housewrap and plywood over the.