Clearance clearance select items sale sale select items compare duravent duraplus 36 in.
Wood stove chimney clearance roof.
Using a heat shield on a single wall stovepipe allows you to reduce the clearances from 18 to 6 to the wall and 9 to the ceiling.
Triple wall stainless steel chimney pipe 6dp 36ss.
This clearance is set up to help prevent any embers from landing on the roof.
Eight to ten inch legs will provide more air space and.
Triple wall pipe through the roof stove chimney kit 6dp kbsc.
Requires only 2 inches of clearance to combustibles.
Product rating is 5.
Class a stainless steel pipe rated to 2100รข for use with high efficiency wood stoves.
If the pipe is farther than 10 feet from the roof peak.
When installing a chimney for a wood stove on a metal roof you ll first need to assess the position.
Carson dunlop associates at reviewers sketch above shows that the minimum chimney height above a wood burning fireplace is 15 and that a shorter minimum of 5 may be acceptable above the draft hood of a gas furnace is allowed in some jurisdictions.
If there is a steep roof or nearby obstruction the chimney will need more length above the roof to meet code.
Roof clearances for wood burning fireplaces wood burning fireplace roof clearance requirements.
All components twist lock together for a secure system.
The chimney is a minimum for 3 above the uphill side of the roof and 2 higher than anything within 10 feet.
Six inch diameter pipe is suitable for all our stove models.
Typical clearance between a wood or coal fired heater and the nearest combustible surface is 36 unless approved heat shields have been installed.
You can leave solid pack chimneys exposed and braced.
Many think stovepipe can run from the wood stove right up through the ceiling and roof.
Duravent duraplus 6 in.
Drill a small hole in this spot to mark the chimney s center.
Place the chimney where it would be related to the stove and mark the center of the chimney on the ceiling.
Using a compass draw out the chimney s diameter.
At this point we cover everything in the rule.
The free standing fireplace photo at page top is less than 12 from wood paneling which is in turn installed on a wood framed wall this is an unsafe installation that should not be used.
The chimney in this example must extend 52 above the roof measured from uphill side of the chimney.
If the stove legs provide less than 6 inches of clearance 2 to 4 inches of hollow masonry laid to pro vide air circulation with a sheet of 24 gage sheet metal between the floor and the masonry is recommended.
Most of the double wall stove pipe allows for 6 clearance from wall combustibles and 8 from ceiling combustibles.